Installation Guide
Page 10 
CORNER LOCATION FRAMING 
WARNING: Install the hearth protector only 
as specified. The extension must extend a mini-
mum of 16" in front of the stove door opening 
and must be 37 1/2" wide minimum. Refer to 
(Page 6) for calculation of R, and K values. 
NOTE: No floor protector is needed directly under the Model 51ZC Cabinet, only the hearth protector 
is needed. 
FIGURE 9 
. 
i 
CHIMNEY CAP 
STROM COLLAR 
ROOF FLASHING 
2" X 4" STUDDING 
CHIMNEY PIPE  
METAL FIRE STOP 
USE FIRE CODE SHEET ROCK 
2" X 4" STUDDING 
A SINGLE HEADER MUST BE INSTALLED ABOVE CABI-
NET. VERTICAL 2" X 4"‘s MUST BE TURNED FLAT. 
NOTE: FINISHED WALL MUST BE 2" IN FRONT OF FACE 
OF ZC CABINET (WITHOUT HOOD TRIM ATTACHED).  
NOTE: A DOUBLE HEADER MUST BE USED ON A LOAD 
BEARING WALL. 
34 3/4" 
37 1/2" 