Operating instructions

SECTION If
MINIMUM CLEARANCES
WALL
INSTALLATION
The BUCK STOVE Models 26000-8 and
27000-B must be installed
in
compliance with
the instructions contained in this manual.
Clearance from
combustible
walls
and
ceilings.
The minimum lateral distance between any
part of the BUCK STOVE models 26000-8
and 27000-B are shown in figures 1 and
2.
Floor Protection
If a freestanding model of the BUCK STOVE
is
to
be installed
on
a combustible floor, a non-
combustible pad must be placed below it
to
protect the floor from radiant heat and burn-
ing material from the stove.
The pad must meet the following minimum
specifications:
A NOTE:
Oimonsion, Shown
."-
Minimum
CI
••
r."""
III
Combu
..
i:'",
Wilt
flO()( ProtoctOt _
Minimum
Sin
Chart
"A"
FIGURE 1
Woll
16"
Use a Listed Floor Protector or a Floor Pro-
tector made of a non-combustible inorganic
material equal
to
3/8"
Thk. millboard having
a thermal conductivity of
K:::
0.84
BTUlF2HoF
inches.
Ft.
2
H.
Degrees
F.
ANOn:
Oimll'\'ttom
5hOYWfl
.q
Minimum C
..
.,..nc.
to
Co~iUi'lb~
Waif.
16"
The
BUCK
STOVE
must
be positioned on
the pad so that there is a minimum
of
16"
from the front of the
door
to the front of the
pad, and a
minimum
of
8"
measured
horizontally from the sides of the stove to
the sides
of
the pad.
CHART
A
BUCK STOVE
MODEL
26000-8
27000-8
2S000
Floor
Protector
MINIMUM
SIZE:
48"
x
4S"
x
3/S"
53"
x
4S"
x 3/8"
54"
x
54"
x 3/8"
FIGURE 2
CORNER
INSTALLATION
CAUTION: There must
be
a minimum of
18"
from any single wan pipe
to
a combustible
wall.
If there is not
18"
from single wan pipe
to
the
combustible
waH,
a wall
protector
must
be used.