Operating instructions
WALL
INSTALLATION
MINIMUM CLEARANCES
The BUCK STOVE Model 28000
The BUCK STOVE Model 28000 (NOT UL
LISTED)
must
be
installed
in
compliance
with
lhe
instructions
contained
in
this
manual.
The minimum lateral
distance
between
any
part
of
the 28000 and a
combustible
wall
is
36".
(See Figures 3 &
4)
Floor
Protection
If a
freestanding
model
of
the
BUCK STOVE
is
to
be
installed
on a
combustible
floor, a non-
combustible
pad
must
be
placed
below
it to
protect
the
floor
from
the
radiant
heat
and
burning
material
from
the stove.
Use a
listed
Floor
Protector
or
a
Floor
Protec·
tor
made
of
a
non-combustible
inorganic
material
equal
to
3/8"
Thk.
millboard
having
a
thermal
conductivity
of
K::::
0.84 BTU in.
(See Page
14)
Ft.aH. Degrees
F.
With
Wall
Protector
...
NOTE:
OH1,*o~n,
Shown
.re
Mfllimum
CI.,,·",nc::1'
to
Comb....
,,:>
..
w.1l
floot
P,ot«Cla,
...
M,n""
...
m
S,lt
Ch~1
"A'"
t6"
FIGURE 3
)6"
Wall
Refer to
NFPA-211-1980,
(b),
except
that
the
MINIMUM
DISTANCE TO A PROTECTED
WALL
SHALL
BE
18".
"UNLISTED
PRODUCTS MUST BE INSTALLED
WITH THE ACCEPTANCE OF THE AUTHORITY
HAVING JURISDICTION
AND
IN
ACCOR·
DANCE WITH THE MANUFACTURER'S IN-
STRUCTIONS",
The BUCK STOVE
must
be
positioned
on the
pad so there is a
minimum
of
16"
from
the
front
of the stove
to
the front
of
the pad and a
minimum
of
8"
from the side
of
the
firebox
opening
and
the side
of
the
pad.
£
HOff:
OH1\1n~ll1o
Shown
,'.
MIOtMl,.jm
C~..,~.
10
Cot'tOu'hb'-:
W.U
FIOOt P,ott<JOf
""
MtnuTtVm
SIU
Chll1
"A"
3<)'
FIGURE 4 CORNER INSTALLATI'ON
Page 22