Operating instructions
CHIMNEY
The BUCK STOVE Models 26000-B and 27000-B are designed for connection to either
an
8"
inside diameter Underwriters' laboratories, Inc. listed all-fuel residential type
and
Building Heating
Appliance Chimney, or to a masonry chimney which meets the specifications of
the
National
Fire Protection Association's
211
Code and has a minimum cross section area of
50
square
inches
(7
1/4" x 7 1/4" or
8"
round).
CAUTION:
Use
only
U.l.
Listed type HT chimney rated
at
2100° F for freestanding installations.
TOOLS FOR INSTALLATION
1/2"
• 9/16" combination wrench
7/32" drill bit and drill
3/8" magnetic socket chuck adapter, 3/8" wrench (box or socket) or adjustable wrench.
PREPARING THE STOVE FOR INSTALLATION
1.
Remove the protective plastic wrapping from the stove.
2.
Inspect
the
stove for any obvious physical damage.
3.
Plug the power cord into a
115
VAC
outlet to test the motor and fan. Place
the
blower
control in the "MANUAL" position to test.
4.
Check the primary air draft controls to ensure that they slide freely and will lock into
position when the control knobs are tightened.
5.
Check the operation of
the
damper control to ensure that it will open and close properly.
STAND MOUNTING
FIGURE 5
STAND KIT
L-1
PEDESTAL KIT
P-1
STOVE MODEL
"A"
Dimension
26000-B Little 1
1/4"
270oo-B Regular
2
1/2"
28000 Big
-
STOVE MODEL
"A"
Dimension
26000-B Little Flush to Front
27000-B Regular
1 1/4"
28000 Big
6. Open and remove the doors,
firedo~s,
side liners and the cast refractory material from
the bottom of the stove to facilitate Installation.
7.
Attach the legstand by tilting the stove
on
its back, center the legstand on the bottom
of
the stove and position back 7/32" from the dimension shown in chart left
of
Figure
5.
When positioned, drill holes through holes of mounting stand and attach using 1/4" Dia.
self-tapping screws provided.
(See
Figure 5.)
Page 23