Operating instructions
--he Zero-Clearance BUCKMATE Fireplace Cabinet Model ZC-2-01 (hereafter referred to
as
the
UUCKMATE) is designed to facilitate the installation of a BUCK STOVE Model 26000-B (hereafter
referred to
as
the BUCK STOVE Fireplace (FP) )
in
a family dwelling, where minimum clearance
is
desired. The Zero Clearance BUCKMATE Fireplace Cabinet Model
ZC-3-01
is designed
to
facilitate the installation of a BUCK STOVE Model 27000-B or the
FP-201
Fireplace. Just
as
the
name implies,
the
Zero Clearance BUCKMATE may be installed in direct contact with building
(onstruction. Installed properly, the unit then provides a safe, insulated housing for
the BUCK
STOVE Fireplace.
tlormally, the installation will be accomplished in
two stages:
1)
Installation of the BUCKMATE
f:ireplace Cabinet and
associated framing and morlarwork, and 2) later installation of
the
BUCK
~3TOVE
(FP)
into the BUCKMATE Fireplace Cabinet.
Note·
The ZC-3-01 and
FP-2.01
are in-
~.
tailed
at
the factory as one unit.
INSTALLATION PRECAUTIONS
The following precautions are mandatory for a safe installation:
1\.
Compliance with local building codes and regulations is mandatory.
U.
Be
careful not to damage unit
in
handling and unpacking component parts and accessories.
C.
The only factory approved chimney pipes to be used are Underwriters Laboratories listed
Simpson Dura-Vent Chimney ModeI8-DCR and 8SDP, Standex Model
"S",
Metal-Fab Model
"A"
and
"TG",
and Secunty Model
"ASHT"
vented to the outside of the building.
D.
The chimney must extend a minimum of three feet above the highest point where it
penetrates the roof (three
feet above a flat roof or up to a 2/12 pitch roof), and the chimney
must extend a minimum
of
two feet higher than any portion of the bUilding within ten feet
of
the chimney. The minimum height is
14112
feet. The maximum height is 42 feet. A two-inch
clearance must be maintained between
the chimney and any combustible materials
at
all points.
fe:.
A rain cap must
be
used to terminate the chimney to prevent down-draft. Use the factory
approved rain cap which is approved for
the type chimney being installed.
F.
Use only New Buck Corp. Roof Flashings when installing the BUCKMATE Cabinet, Chimney
and applicable Fireplace with
the 1700° Simpson Dura-Vent
OCR
Chimney.
n.
The BUCKMATE Fireplace Cabinet is not intended for use in mobile homes.
H.
DO
NOT build a fire directly inside the BUCKMATE. It is designed solely for housing the
BUCK STOVE Fireplace.
SELECTING A CHIMNEY INSTALLATION AND LOCATION
Chimney Gop
1here are
tw<?
basic types of chimney installations possible with the BUCKMATE; Straight up
lilrough a
celJng,
and chase installalion, either outside or inside. These are normally used as
hllows:
A CAUTION R f t h' f
..
• e er 0 c Imney manu acturers
instructions for assembly and disassembly
of chimney parts.
Be
sure to follow chimney
instructions for proper clearnaces
to
combust-
ibles and proper air spacing required.
Simon CoHa,
Chln1l1&Y
Cnp
-
Flashmg
~N-·-·-Melat
FireSIOP
~'''~
",.~~.-.
_ - Storm Collar
"
~
\
._
Fioshoog
_______
.
__
':0,
::-:---
Ch,mn<y
p,pe
--
=
·f~-
Melal
FIleslop
- l C
Cab,nel
Z C
Cablnel
FIGURE 1
Through
Ceiling
&
Normal
Pitch
Roof
FIGURE 2
Through
High
Pilch
Roof
Page 32