Operating instructions

ELECTRICAL INSTALLATION
Electrical procedures:
The
BUCKMATE is not pre-wired;
an
electrician must wire
the
8UCKMATE into the home wiring system using
No.
14
AWG
(with ground wiring)
as
minimum
in
accordance with local wiring codes.
(See
Figure
4.)
1.
Remove receptacle cover.
2.
Remove receptacle from mounting box.
3.
Run No. 14
AWG
wire directly from house wiring in through the Field Connector in
the lower right side of the BUCKMATE. Leave 4-6 inches of wire extending out of
the
box.
4.
Tighten Field Connector around wire.
5.
Wire receptacle (black, white, and ground) and resecure to mounting box.
6.
Replace receptacle cover.
GROUND
HOUSE
WIRING
TO STUD
TO HOUSE
WIRING
FIGURE 4
POWER HOOK-UP
l'lOTE: During installation of
the
ZC-3-Q1/FP-201
combination, if it
is
ant.i~ipated
~hat
the
FP-201
may
be
replaced
at
a later date with the Model 27000-B Stove, prewmng as Illustrated above
is
recommended to insure convenience.
Page 44