Operating instructions
FIRE CURTAINS
Do
not leave the fire unattended with the fire curtains open. Heat safely by burning with
the
curtains closed except for start-up of the fire and reloading of wood.
PRECAUTIONS:
Do
not overfire. If unit
or
chimney connector glows,
you
are overfiring. Keep furnishings
and
other combustibles
far
away
from
the
appliance.
INSTALLATION
OF
OPTIONAL DECORATIVE GAS LOGS
The FP-201/ZC-3-01
is
designed
to
house the installation of decorative gas logs in accordance
with the National Fuel Gas Code,
ANSI
Z223-1-1980. The following steps must be taken for
pro-
per installation:
1)
Remove the front trim panel
from
the
cabinet
(3
vertical screws
on
each side).
2)
Remove the knock-out
in
the left bottom side of the outer cabinet. Remove
the
insulation
(1"
diameter) directly behind the knock-out.
3)
Remove the pipe cap from the pipe extending from the left bottom side of the
FP-201
Fireplace.
4) Remove the left side refractory
from
the
unit. Using a coal chisel and hammer, remove
the knock-out
in
the lower side of the refractory. Replace side refractory and secure in
place
as
previously installed.
5) Install and use a gas appliance which conforms
to
the above code. Follow the manufact-
urer's installation instructions exactly for
the
installation and operation of the decorative
gas appliance.
6) Reinstall the front trim panel.
INSTALLATION
OF
OPTIONAL OUTSIDE AIR KIT (MODEL OA-201)
The major parts
of
the
outside air kit
are
factory installed.
You
will have
to
complete
the
assembly
as
follows:
1)
Prior
to
framing the unit, complete the Outside Air
Kit
by connecting and running
4"
dryer pipe from the unit
to
a designated outside air pick-up wall.
2)
Use
the
vent hood provided
to
complete installation.
WARNING: Install the outside air ductlng on a plane level to
or
lower than the connection
Joint on the cabinet. Installations with the vent hood higher than the connection may cause
a chimney-effect draw and a house fire may result.
INSTALLATION
OF
OPTIONAL GLASS DOORS (MODEL BFG-201)
Installation
of
the optional glass doors is simple.
1)
Using a phillips head screw driver, simply remove the brass screws on top and sides
of the brass at the fireplace opening. Remove brass trim and set aside.
2)
Open
and
inspect the glass door kit. The entire kit includes the door framing, left
and
right doors, and four mounting screws.
3)
Now, open the doors and set the door assembly into the fireplace opening with the door
handles
to
the bottom.
4)
While holding the unit
in
place,
use
a
1"
socket
or
nutdriver and secure the doors to the
fireplace by screwing the self-tapping screws into the holes which previously were used
to
hold the brass trim in place. Door installation is now complete.
CAUTION: To prevent skin burns, be sure
to
mount the
doors
with
the handles
to
the
bottom.
Page 48