User's Manual

Electrical Specs:
The Budderfly Switch Dimmer can handle multiple load types. Below is a
summary of these loads:
Voltage: 120/277 VAC - 60Hz
Maximum Switching Loads:
Tungsten
@120V 950W
@277V 2200W
Electronic Ballast
@120V 950W
@277V 2200W
Standard Ballast
@120V 950W
@277V 2200W
Maximum Phase Control Loads:
Tungsten
@120V 950W
@277V 2200W
Maximum 0-10v Dimming : 30mA
Operating Temperature : 10
o
C to +40
o
C
Certification : ETL & FCC in progress
For indoor use only
Derating Chart:
When combining multiple Dimmers in a gang box, the device must be derated.
Check the below chart for details.
Warranty:
Budderfly LLC warrants to the original consumer purchaser and not for the
benefit of anyone else that this product at the time of its sale by Budderfly is
free of defects in material and workmanship under normal and proper use for a
period of three (3) years from date of delivery to you. Budderfly’s only
obligation is to correct such defects by repair or replacement, at its option, if
within such three year period the product is returned prepaid via Budderfly’s
Returned Materials Authorization (RMA) process to Budderfly LLC, Att: Quality
Assurance Department, 4 Corporate Drive, Suite 387, Shelton, CT 06484. In no
case is product to be returned without first obtaining an RMA.
This warranty excludes and there is disclaimed liability for labor for removal of
this product or reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions. There are no
other or implied warranties of any kind, including merchantability and fitness
for a particular purpose, but if any implied warranty is required by the
applicable jurisdiction, the duration of any such implied warranty is required by
the applicable jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to three years.
Budderfly is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform this warranty
obligation. Budderfly’s liability on any claim for damages arising out of in
connection with the manufacture, sales, installation delivery, or use of the
product shall never exceed the purchase price of the product. The remedies
provided herein are the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
Load Type
Voltage
No Sides
Removed
1 Side
Removed
2 Sides
Removed
Incandescent
120V
950 W
600 W
600 W
277V
2200 W
1350 W
1350 W
FCC NOTE
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY
RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH
MODIFICATIONS OR CHANGE COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.