10
Installation examples
Logano G115 WS US/CA – 6 720 813 418 (2019/09)42
10 Installation examples
Key to abbreviations
Fig. 42 Multiple circuits with circuit valves
[1] Baseboard
Fig. 43 Multiple circuits with circuit valves
[1] Baseboard
KR Check valve SH Heating circuit adjuster
MAG Expansion tank SV Pressure relief valve
PH System pump THV Thermostatic radiator valve
PW Hot water pump WH Water compensation pipe (diversion)
7 747 019 141-40.1RS
SV
PH
MAG
THV
G125 WS/NA
1
1
1
G115 WS/NA
7 747 019 141-41.1RS
SV
PH
KR
MAG
G125 WS/NA
1
1
1
G115 WS/NA