Install Instructions

Safety Considerations 1
5
We reserve the right to make any changes due to technical modifications.
Installation and maintenance instructions Logano G215 US oil/gas-fired boilers Issue 2014/10
1 Safety Considerations
1.1 With respect to this manual
This installation and maintenance manual contains
important information for the safe and correct
installation, initial start-up and maintenance of this
boiler.
The oil and gas fired boiler Logano G215 is generally
referred to below as a boiler.
The installation and maintenance manual is provided for
technicians who have been trained and have experience
in working with heating systems and oil and gas fired
installations.
1.2 Application Purpose
The boiler can only be used for hot water space heating
and water heating for single and multi family homes.
Please note the details on the rating plate and the
specifications (Î Chapter 3, page 8) to ensure the
correct use of this equipment.
1.3 Guideline of Notice
The following symbols are used in this manual:
Î Cross references
Cross references to a specific section or another
document are identified with an arrow Î .
1.4 Please observe these notes
Observe all local codes and standards during installation
and operation:
Local building code regulations regarding
installation, combustion air supply and flue gas
systems as well as connection to a chimney.
Electrical code requirements for connection to the
power supply.
The technical rules of the gas supply company
regarding the connection of a gas burner to the gas
system.
Regulations and standards regarding safety
equipment of the heating system.
1.4.1 If you notice a smell of gas
1.4.2 Installation tips
WARNING!
DANGER TO LIFE
Identifies possible risks that may lead to
serious injury or death if appropriate care is
not taken.
CAUTION!
DANGER OF INJURY/
SYSTEM DAMAGE
Identifies a possible dangerous situation
that can lead to mild to moderate personal
injury or physical damage.
NOTICE
Tip for optimum use of equipment and
adjustment as well as useful information.
NOTICE
Use only original Buderus components.
Losses caused by the use of parts not
supplied by Buderus are excluded from
the Buderus warranty.
WARNING!
DANGER TO LIFE
through the explosion of volatile gases.
If you can smell gas there is a risk of
explosion.
z Extinguish all open flames. Do not
smoke. Do not use lighters.
z Prevent sparks.
Do not operate electrical switches,
including telephones, plugs or door-
bells.
z Close the main gas shut-off valve.
z Open windows and doors.
z Warn all occupants, but do not use
doorbells.
z Call gas company from outside the
building.
z If you hear gas escaping, immediately
leave the building, prevent others from
entering and notify the police and fire
brigade from outside the building.
WARNING!
DANGER TO LIFE
through the explosion of volatile gases.
z Work on gas components must be
carried out by qualified and authorized
personnel only.