Installation Instructions
4
Installing the boiler
Logano G115 WS US/CA - Technical specifications are subject to change without prior notice.
15
4.2 Reversing boiler door
The burner door is factory-fitted with the hinges on the
right – the burner door opens to the right.You can change
the burner door hinges over to the left-hand side if desired
to suit the installation site.
Remove the burner hood/burner door panel first
(Æ Chapter 3.1, page 12).
V Removing the burner door (Æ Chapter 3.1, page 12).
V Unscrew the hinge bolts and remove the hinges.
V Mount the hinges on the left-hand side of the boiler
using the hinge bolts.
Fig. 8 Reversing the burner door (boiler heat
exchanger attachments)
1 Hinge bolts
2 Hinges
V First remove the hinge lobe bolts and then the hinge
lobes. Mount the hinge barrels on the left-hand side of
the boiler using the hinge-barrel bolts.
V Hook the burner door with the hinge lobes onto the
hinges.
V Check that the heat exchanger baffles are placed hori-
zontally (Æ Chapter 6.3, page 29).
V Close the burner door and secure with the two hexa-
gon-head bolts.Tighten the hexagon-head bolts evenly
(approx. 90 Lbs/inch) so that the burner door seals
properly.
Fig. 9 Reversing the burner door (door attachments)
1 Hinge-barrel bolts
2 Hinge lobes
3 Burner door
4 Hinges
5 Heat exchanger baffle plates
7 747 019 141-08.1RS
12 21
If the burner door hinges have been changed
over to the left-hand side, the burner cable
must be disconnected from the burner before
opening the burner door.
7 747 019 141-09.1RS
1
4
5
2
3