Operating instructions

Extended functions8
52 Operating instructions RC30 programmable room thermostat • Issue 02/2006
We reserve the right to make any changes due to technical modifications.
Release the "Heating circuit" button.
Then the standard display is shown again.
Hold down the "Prog" button and select the "NEW PROG" heating
program with the dial.
Release the "Prog" button.
You can now enter the first switching point. Proceed in the same
way as for entering a heating program (see Chapter 8.12 "Creating
a new heating program", page 45).
Activating a new DHW program
Hold down the "Prog" button and select the "OWN PROG" heating
program with the dial.
Release the "Prog" button.
Restoring the factory setting
Hold down the "Prog" button and select the "TO HC T PROG"
heating program (HTC = heating circuit time) with the dial. The ON
and OFF-Times for DHW are linked again to the chosen heating
program.
Release the "Prog" button.
HEAT CIRC
DHW
ACTUAL
ROOM TEMP
21.5
°
+
SWITCH POINT
---- ----
--:--
+
+
USER NOTE
In order for the DHW program to be effective, make sure that
"DHW AUTO DAY" is selected as the operating mode (see
Chapter 8.15 "Setting the operating mode for domestic hot
water", page 50).