Operating instructions
Logamatic EMS RC35 programming unit - Subject to technical modifications
21
Commissioning
5
5.4 Detailed commissioning
B Check whether the factory settings in menu SERVICE\SETTINGS suit your heating system.
B Note down modified settings if needed.
5.5 System handover
B Ensure that no temperature limits for central heating and DHW have been set at the boiler
programming unit, so DHW and flow temperature can be regulated via the RC35 programming
unit.
B Explain to the customer how the device works and how to operate it.
B Inform customer about the selected settings.
DHW Have you installed
domestic hot water?
yes, no no
4)
What should be used
for domestic hot water
heating?
3-way
switching
valve
cylinder
primary
pump
3-way
switching
valve
5)
To which temperature
should your domestic
hot water be heated?
30 °C to
80 °C
60 °C To be able to change the
DHW temperature, set
DHW on the boiler
programming unit to
“AUT” or enable DHW.
SOLAR MODULE Have you installed a
solar module?
yes, no no
1)
1) Not possible or available on boilers with UBA1.x or DBA.
2) Not possible on boilers with UBA4.
3) Only possible on boilers with UBA4.
4) Not possible or not available with boilers with DBA.
5) Not available with boilers with UBA1.x, DBA or UBA-H3.
Check whether further settings are required using the checklist on page 19.
SHORTCUT\ Menu item
Input
range
Factory
setting Other information
Tab. 8 Quick operation menu navigator