Operating instructions

Principles of operation
Logamatic EMS RC35 programming unit - Subject to technical modifications
16
4
4.6 Setting the room temperature for particular heating circuits
If the heating system comprises several heating circuits (Æ page 27), you can adjust the room
temperature for selected heating circuits with .
Only heating circuits that are not equipped with an RC2x remote control unit will be displayed. No
selection is possible if there is only one heating circuit. All RC35 heat. circuits have the same room
temperature set values.
If no selection is possible or if you select RC35 heat. circuits, you will be setting the same
temperatures as described on page 15.
B Open the flap (by pulling the recessed grip on the left).
B Press and release.
B Select the heating circuit (Æ page 26 – 28). Heating circuit selection is not available if only one
heating circuit is installed.
B To change the day room temperature: hold down and simultaneously turn rotary selector
until the required temperature is displayed. Release .
The required temperature is saved.
B Turn rotary selector to switch to the night room temperature.
B To change the night room temperature: hold down and simultaneously turn rotary
selector until the required temperature is displayed. Release .
The required temperature is saved.
B Press several times or shut the flap to return to the standard display.
The modified room temperatures are now active.
NOTICE: System damage due to frost!
If room temperatures are set below 10 °C, rooms may cool down so much that pipes in
external walls (for example) may freeze in cold weather.
B Set room temperatures higher than 10 °C.
If “shut-down mode” is selected as the night setback mode, the heating system will be
switched off at night. A nighttime room temperature cannot be set. The display will show
a message to this effect.