Operating instructions

Logamatic EMS RC35 programming unit - Subject to technical modifications
37
Operation with the user menu
5
5.6.6 Setting room temperatures
The room temperatures menu item is only available for heating circuits without a remote control
unit (the first case below). In the other two cases, the room temperatures menu item is not
displayed.
Possible case scenarios:
Heating circuits without remote control (Æ page 53, setting “none”): different room
temperatures are possible for each circuit, in contrast to the RC35 heating circuits. The room
temperature is set as described below.
RC35 heat. circuits: the room temperatures are the same for all heating circuits assigned to the
RC35. For the RC35 heating circuits, you need to set the room temperature using , not in the
user menu (Æ page 16).
Heating circuits with a remote control, e.g. RC2x, RC20/RF: you set the room temperatures at
the remote control, not at the programming unit.
Setting room temperatures with user menu\switching program
Here you can set the room temperature for the heating circuit previously selected in the switching
program.
1. Open the user menu.
2. Select switching programme.
3. Select the heating circuit (Æ page 26 – 28).
4. Select room temperatures.
5. Set the required room temperature.
6. Turn the rotary selector to switch between the temperatures for day and night mode.
If “shut-down mode” is selected as the night setback mode, the heating system will be
switched off at night. A nighttime room temperature cannot be set. The display will show
a message to this effect.
NOTICE: System damage due to frost!
If room temperatures are set below 10 °C, rooms may cool down so much that pipes in
external walls (for example) may freeze in cold weather.
B Set room temperatures higher than 10 °C.