Operating instructions

Operation with the user menu
Logamatic EMS RC35 programming unit - Subject to technical modifications
38
5
5.7 Setting a DHW program
With the setting by heating circuit (factory setting), the start and stop times for DHW heating
follow those of the selected switching program. This ensures that DHW is available during the
heating phases (day mode).
If you want to enter a separate DHW program, we recommend:
Only charging the DHW cylinder once in the morning before the heating start time and possibly
also programming another heating phase in the evening if more hot water is regularly needed at
that time.
This would allow you to significantly reduce your energy consumption even further.
To set a DHW program which is independent of the heating phases:
1. Open the user menu.
2. Select switching programme.
3. Select the domestic hot water heating circuit.
4. Use change switch point to enter, delete or modify a switching point (Æ page 34) or enter a
new program.
5. Save the program as user defined 1 or select do not save to cancel.
6. Check that automatic operation is set for operation mode\domestic hot water to make
sure that the program you have set is also active (Æ page 30).
5.8 Setting a DHW circulation program
You can use a DHW circulation program
1)
to enter the start and stop times for the DHW circulation
pump independently of the switching program for the heating system. Follow the same procedure
as for entering a DHW program (Æ Chapter 5.7).
If you occasionally need more DHW outside the set time, you can activate the DHW
heating for a short time (“Heating up DHW once”, Æ page 18).
1) This function depends on the boiler used.