5.15 Setting thermal disinfection
If this function
1)
is activated, DHW is heated once a week or once a day to a temperature sufficient
to kill pathogens (e.g. legionella).
1. Open the user menu.
2. Select therm. disinfection.
3. Set yes or no.
If thermal disinfection is switched on:
4. Set the temperature to which the hot water should be heated during thermal disinfection (factory
setting: 70 °C).
5. Set the day of the week (factory setting: Tuesday).
6. Set the time (factory setting: 01:00 h; can only be started on the hour).
5.16 Calibrating the room temperature display
If there is a separate thermometer near the programming unit, it may show a different room
temperature to that shown on the programming unit. If you wish to adjust (“calibrate”) the
programming unit to match the thermometer, you can use the room temp. correct. function.
Before matching the room temperature, consider the following:
Is the thermometer more accurate than the programming unit?
Is the thermometer located close to programming unit so that they are both subject to the same
heat influences (e.g. sunlight, fireplace)?
Instead of making the setting via the user menu, you can use the following shortcut:
B Press and hold down .
B Open flap.
B Turn rotary selector at the same time to set the number of hours (0 to 99).
1) The function depends on the boiler used
WARNING: Risk of scalding from hot water at the draw-off points!
During the thermal disinfection process the DHW can be heated to a temperature
above 60 °C.
B Do not open a DHW tap without mixing in cold water as well during or after the
thermal disinfection process.