Check the magnesium anodes for decomposition.
When the diameter is reduced to approx. 5/8" (15 mm), replace the
magnesium anode.
Screw the magnesium anodes back into the cover.
Fig. 21 Checking the upper magnesium anode
[1] Hex bolt
[2] Magnesium anode
Check the magnesium anode installed from the side
Drain the DHW tank as described in the 9.1 chapter.
Remove cleanout cover ( Fig. 19, page 16), if it is not already
removed.
Check the magnesium anodes.
When the diameter is reduced to approx. 5/8" (15 mm), replace the
magnesium anode.
To loosen the eyelet for the grounding cable [8], unscrew nut M8 [9].
Undo nut M8 [7].
Remove cleanout cover [3] from magnesium anode [1].
Install new magnesium anode with the aid of the hardware provided.
Fig. 22 Replacing the magnesium anode
Key to Fig. 22:
[1] Magnesium anode
[2] Gasket
[3] Cleanout cover
[4] Insulating sleeve
[5] Dished washer
[6] Serrated washer
[7] M8Nut
[8] Ground wire eyelet
[9] M8Nut
9.4 Re-commissioning after performing maintenance
Put the cleanout cover [4] back in place together with the new gasket
[2].
Thread hex bolts [5] into cleanout cover [4] "hand-tight".
Then use a torque wrench to tighten the hex bolts to 18-22 lbf-ft
(25 – 30 Nm).
Fill the DHW tank and restart the heating system.
Check all connections and the inspection port for leaks.
Replace the cleanout cover shroud.
Reinstall the PS jacket cover ( Fig. 2, page 5) on the DHW tank.
Fig. 23 Reinstall cleanout cover
[1] Inspection port
[2] Cleanout cover gasket
[3] Magnesium anode
[4] Cleanout cover
[5] Hex bolts
[6] Cleanout cover shroud
6 720 800 155-23.1ITL
CAUTION: Risk of tank damage from a faulty gasket!
To prevent the DHW tank from leaking, install a new
cleanout cover gasket upon completion of cleaning
and maintenance.