9.4 Re-commissioning after performing maintenance
Put the cleanout cover [4] back in place (top or side) together with the
new gasket [2].
Thread hex bolts [5] into cleanout cover [4] "hand-tight".
Then use a torque wrench to tighten the hex bolts to 18-22 lbf-ft
(25 - 30 Nm).
Fill the DHW tank and restart the heating system.
Check all connections and the inspection port for leaks.
Replace the cleanout cover shroud.
Reposition the PS top cover on the tank.
Fig. 22 Reassembling the inspection port
[1] Inspection port
[2] Cleanout cover gasket
[3] Magnesium anode
[4] Cleanout cover
[5] Hex bolts
[6] Cleanout cover shroud
CAUTION: Risk of tank damage from a faulty gasket!
To prevent the DHW tank from leaking, install a new
cleanout cover gasket upon completion of cleaning
and maintenance.