GEN4000DF 4000 Surge Watts / 3500 Running Watts DUAL FUEL GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance. Every effort has been made to ensure the accuracy of this manual. These instructions are not meant to cover every possible condition and situation that may occur. We reserve the right to change this product at any time without prior notice.
GEN4000DF Portable Dual Fuel Generator FEATURES: 4000 Surge Watts / 3500 Running Watts* 4-Stroke OHV Engine 212cc Recoil Start 7.0 HP Dual Fuel Engine (Propane Tank Not Included) • 1 - 12V D/C Outlet • 4 - 120V A/C Outlets • 1 - 120V RV Outlet • Engine Run Time: 10 Hours @ 50% Load • Runs 12 hours @ 50% Load on 20 lbs of LPG Fuel • Low Oil Shutdown • AVR Automatic Voltage Regulation • EPA Approved • Noise Level: 69dB @ 0% Load • Oil Capacity: 18.6 ounces • Fuel Capacity: 3.
TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS .............................................................................................. 4 PACKAGE CONTENTS PACKAGE CONTENTS .......................................................................................................................................... 9 COMPONENTS .....................................................................................................................................................
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment. Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand. This is the safety alert symbol.
Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine Modifications (EM). Legal Requirements: Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use of this generator.
Usage: This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included). Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional information consult the devices operation manual or call customer service at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time.
Usage: Misuse of this generator can damage it or shorten its life. Use this generator only for its intended purpose. • Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency. • Allow this generator to run for several minutes before connecting any electrical devices. • Promptly turn off any malfunctioning devices and disconnect them.
In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.
PACKAGE CONTENTS The following items are supplied with this Generator. Verify that all items are included. STOP! If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS GENERATOR TO THE RETAILER. Item List: DC connector wires for charging 12 Volt automotive-type batteries Spark plug wrench 5.9 Ft.
GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator.
PREPARING THE GENERATOR FOR USE Using this Generator for the First-Time STOP! The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after reading this section, call 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time for customer service.
Step 2 - Add Gasoline or Connect Propane Tank Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. • Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental damage.
Step 3 - Ground the Generator Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location.
Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. • Always allow several minutes for the engine to cool before refueling. • Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental damage.
STARTING THE GENERATOR STOP! Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. Disconnect all electrical loads from this generator before attempting to start. To start this generator: 1. Confirm that there are no electrical devices connected to this generator.
USING THE GENERATOR • USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY. • Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. After the engine has been running for several minutes, electrical devices may be connected to this generator. AC Usage Electrical devices running on AC current may be connected according to their wattage requirements.
Even though this generator has an overall rated wattage of 4000, do not attempt to draw more than 3500 Watts from the 120 Volt outlet. Draws higher than 3500 Watts will damage this generator and void the warranty. NOTE: While this generator is running, power is available from either the standard 120 Volt outlet or the 12 Volt DC outlet. Both 120 Volts and 12 Volts can be simultaneously drawn from this generator.
STOPPING THE GENERATOR To stop this generator: 1. Turn off all connected electrical devices and then unplug them. 2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 3. If using gasoline, turn the fuel valve to the “OFF” position. 4. Set the engine power switch to the “OFF” position. 5. If using Propane, turn the propane tank fuel valve to the “off” position, then turn off the engine power switch.
Checking the Oil Level It is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity. To check the oil level: 1. Verify that this generator is shut down and on a level surface. 2. Unscrew the oil filler/dipstick cap from the engine. 3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap. 4. Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick.
Air Filter Maintenance Routine maintenance of the air filter helps maintain proper airflow to the carburetor. Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when operating this generator in extremely dusty areas. To clean the air filter, remove the foam filter element from the generator and wash it in warm water and household dish detergent. Thoroughly rinse and dry.
STORAGE/TRANSPORT PROCEDURES Do not store gasoline for more than 3 months. Never place any type of storage cover on this generator while it is still hot. When transporting or storing this generator for extended time: • Allow generator to fully cool before moving it. A hot engine and exhaust system can burn you and ignite some materials. • Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.) • Turn the fuel valve to the “off” position. • Disconnect the spark plug.
TROUBLESHOOTING IMPORTANT: If trouble persists, call our customer help line at 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time. Symptom Engine will not start. Cause Engine switch is set to "off." Fuel valve is turned to "closed." Choke is set to “Open/Run”. Engine is out of gasoline. Engine is filled with contaminated and/or old gasoline. Spark plug is dirty. Spark plug boot is cracked. Spark plug is broken. Oil is low. Engine will not start. Spark plugs not sparking. Engine will not start.
GEN4000DF Portable Dual Fuel Generator 23
PARTS DIAGRAM GEN4000DF Portable Dual Fuel Generator 24
GEN4000DF Portable Dual Fuel Generator 25
(EPA Model Generator Doesn’t (EPA Model Generator Include These Parts) Doesn’t Include These Parts) GEN4000DF Portable Dual Fuel Generator 26
GEN4000DF Portable Dual Fuel Generator 27
GEN4000DF Portable Dual Fuel Generator 28
GEN4000DF Portable Dual Fuel Generator 29
GEN4000DF Portable Dual Fuel Generator 30
EMISSION CONTROL SYSTEM WARRANTY Your Warranty Rights and Obligations: The California Air Resources Board, U.S. EPA and Buffalo Corp are pleased to explain the Emission Control System Warranty on your 2015 model year outdoor power equipment engine. California In California, new spark-ignited small off-road equipment engines must be designed, built and equipped to meet the State’s stringent anti-smog standards. Other States, U.S.
such part repaired or replaced under warranty will be warranted for the remainder of the period prior to the first scheduled replacement point for the part. (4) Repair or replacement of any warranted part under the warranty provisions herein must be performed at a warranty station at no charge to the owner. (5) Notwithstanding the provisions herein, warranty services or repair will be provided at all of our distribution centers that are franchised to service the subject engines.