Power LED Operations
This section explains the details of power LED patterns when an event occurs. If there is a corresponding corrective
action described for the code, try it first. If the LED still blinking due to an issue outlined below, contact Buffalo
technical support for assistance.
White
The power LED will blink white during bootup or shutdown.
Red
If an error occurs, the power LED will blink red. The pattern of the blink gives the error code. You can also confirm the
current status by using NAS Navigator2.
Place of Error Code Status
10s Place of Error Code
The LED flashes for 1.0 second every 0.3 seconds. This gives the tens place of
the error code.
1s Place of Error Code
The LED flashes for 0.5 seconds every 0.3 seconds. This gives the ones place
of the error code.
Code Description Corrective Action
E07
The firmware is corrupted.
Contact Buffalo technical support for
assistance.
E11
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, an
air duster, or other tools to remove them.
E12
A rise in the system temperature may have
exceeded the allowable safety value.
Move the LinkStation to a cool location. Do
not place objects in the area around the
LinkStation.
E14
The RAID array cannot be mounted.
Run a drive check on the RAID array by
referring to the “Checking Drives” section
in chapter 4.
E15
The number of bad sectors has reached a
dangerous level.
Replace the drive by referring to the “Drive
Replacement” section in chapter 4.
E16
Unable to find the drive. Re-insert the drive.
E22
Unable to mount the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive.
E23
An error occurred, so the drive was
removed from the RAID array.
Replace the drive by referring to the “Drive
Replacement” section in chapter 4.
E30
An error occurred, so the drive was
removed from the RAID array.
Replace the drive by referring to the “Drive
Replacement” section in chapter 4.