LCD Message Description Corrective Action
E27 Lost Failover
Target
Unable to find the backup TeraStation.
In the main TeraStation's Settings, navigate
to Backup - Failover to reconfigure the
backup TeraStation for failover.
E30 Replace Drive x
An error occurred, so drive x was removed
from the RAID array.
Replace drive x.
Status
After you change settings or format a drive, the current status is displayed on the LCD panel.
LCD Message Description Corrective Action
I10 System Is
Overheating
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
I11 Bad Sectors on
Drive x
The drive has too many bad sectors. Replace the drive.
I12 Degraded Mode Operating in degraded mode. -
I13 Formatting Array
x...
Formatting the RAID array. -
I14 Checking Array
x…
Checking the RAID array. -
I15 Scanning Array x
Data...
Examining the error status of the RAID
array.
Note: Transfer speeds are slower during
the examination process.
-
I16 Creating Array x... Creating the RAID array. -
I18 Rebuilding Array
x...
Rebuilding the RAID array.
Note: Transfer speeds are slower during
the rebuilding process.
-
I19 Filling Array x
with 0s
Writing 0s to the RAID array and erasing all
data.
-
I20 Formatting Drive
x...
Formatting the drive. -
I21 Checking Drive
x...
Checking the drive. -
I22 Filling Drive x
with 0s
Writing 0s to the drive and erasing all data. -
I25 Updating
Firmware…
Updating the TeraStation firmware.
Note: Do not turn off the power during the
updating process.
-
I26 Initializing
Settings…
Initializing all settings. -
I27 Checking USB
Drive x...
Checking the USB drive. -
I28 Formatting USB
Drive x…
Formatting the USB drive. -
I31 Push Func to Use
New Drive x
Displays when pressing the function
button to rebuild the RAID after replacing
the drive.
Press the function button to rebuild the
RAID array.