Area Preset
Normally, area would be reset to zero by holding the
START/STOP switch, 3, down until a “beep” is heard
from the alarm (approximately three seconds) when
in the AREA PRESET calibration mode. However, it
is possible to enter a value other than zero and
measure additional area worked. Area measured
during a previous operation can be entered.
The area preset will appear as a four-digit display, 1,
with the left-hand digit flashing. “AREA,” 8, will also
be displayed in the LCD along with the CAL legend,
2, and FT, 7, or METERS. Use the DIGIT SET, 6, and
DIGIT SELECT, 5, switches, as previously de-
scribed, to change the value to the desired setting or
to zero.
Touch the SET UP/SELECT switch, 4, and the
display will cycle to fault codes, ON/OFF.
55
FAULT CODES ON/OFF
Fault codes can be displayed during tractor
operation or not displayed to allow full operation of
the TPM.
In the event that a fault occurs within the tractor
electrical circuits, a malfunction warning symbol
“READ YOUR MANUAL,” 1, will flash on and off and
the code will be stored.
The tractor is factory set to display normal TPM
functions and to store fault codes. The “OFF” legend,
3, will be displayed.
To view fault codes as they occur, press the
START/STOP switch, 4. The display w ill show the
“READ YOUR MANUAL” symbol, 1, and the “ON”
legend, 2. Press the START/STOP switch again and
the “READ YOUR MANUAL” legend, 1, and the
“OFF” legend, 3, will be displayed.
When “ON” is displayed, fault codes will appear as
they occur and also be stored in memory. When
“OFF” is displayed, the fault code will be stored in
memory and the “READ YOUR MANUAL” symbol, 1,
will be displayed.
56