Installation Guide
HDPC® Rigid Core Vinyl - InstallaƟŽŶ Guide
HDPC® is a rigid waterproof High Density PlasƟĐomposite ŇŽoring with patent pending teĐhnology that uses no
adhesive to bond the vinyl layers together and features the patented UnŝĐlŝĐand Unipush systems and is installed as a glueless
ŇŽaƟng Ňoor. The inƚĞƌůŽĐŬŝng planŬs loĐŬ together to provide a ƟŐŚt water resistant seam, ĐĂn be installed over most ŇŽor surfĂĐĞs,
and is suitable for both residenƟal and light ĐŽŵmeƌĐŝĂůinterior appliĐaƟŽns.
General InformaƟon
1. Flooring should be transported and stored in a neatly staĐŬed fashion on a smooth ŇĂt surfĂĐĞ Be sure to
InspeĐƚthe run numbers/produĐƟon dates on the boxes as diīerent runs may be slightly diīerent, onĐe installed it
beĐŽŵes the installers responsibility. PuƌĐhase enough material to do at least 105% of theĐovered area.
2. Maintain a ĐŽnstant temperature between 60° and 85°F (18.33° and 29.44°C) before, during, and ĂŌĞƌŝnstallaƟŽn.
3. ĐĐlimaƟŽn is ideal, but not requ
ired; ŇŽoring should be stored in the areas that it is going to be installed in for a minimal
24 hours to assure equilibrium.
4. HDPC Vinyl PlanŬs should only be installed aŌĞƌother trades haveĮnished and the jobsite has beenĐůeaned and Đůeared of
debris thatĐould potenƟally damage aĮnished installaƟŽn.
5. No addŝƟonal padding is required as there is an aƩĂĐhed padding to the bĂĐŬ of the planŬs.
6. InspeĐƚ ŇŽoring for damage, defeĐƚs, or shading issues before installa
ƟŽnĐůĂŝms for visual defeĐƚs will not be aĐĐepted
ĂŌĞƌĐuƫng and/or installed.
7. Mix and install planŬs from several diīerent ĐĂƌtons during installaƟŽŶ to ensure a random appearanĐe.
8. Leave 1/4 inĐh gap for expansion around the enƟre perimeter of theŇŽoring.
9. T moldings are reĐommended at all doorways to prevent separaƟŽn or buĐŬůŝng issues due to adjoining rooms.
10. Flooring should be proƚĞĐƚed from direĐƚ exposure to UV light by using shades or blinds when neĐessary.
11. ůůŇŽoring will sĐƌĂtĐh, please beĐauƟous when moving or transpoƌƟng items ĂĐƌoss your ŇŽor as sĐƌĂtĐhes are not a
warranted issue.
Pre-InstallaƟon
SubŇoors:
PlanŬsĐan be installed over a variety of subŇŽor surfĂĐĞs inĐůƵdinŐĐonĐƌete on all grade levels, wood and many other exisƟng hard
surfĂĐĞŇŽors. The subŇŽors must beĐůean, smooth,ŇĂt, solid (no movement), and dry. Do not install planks over Ňoors that are
sloped for drainage. Any uneven areas greater than 3/16” in a 10 foot radius should be leveled with a Portland Đement based
patĐhinŐĐompound. Wellmade Vinyl PlanŬis impervious to water damage but they do not prevent the transmiss
ion of moisture.
Care should be taŬen to Ŭeep moistureĨƌŽŵĐolleĐƟng on either side of theŇŽoring to prevent the growth of unhealthy mold and
mildew.
Concrete SubŇoors:
PlanŬsĐan be installed over ĐŽnĐƌete on all grade levels; a moisture barrier is reĐŽmmended but not required, and shouldĐonsist of
at least a 6 mil polyethylene Įlm with the sheets overlapping 6” and taped to prevent moisture migraƟng to theŇŽoring. Moisture
vapor emissions should not edžĐeed 5 lbs./24 hour per 1,000 sq. when
tested with the AnhydrousĂůĐŝum Chloride Test in
aĐĐŽƌdanĐe with ASTM F 1869 or 85% RH in aĐĐŽƌdanĐe with ASTM F 2170 “Standard Test Method for Determining RelaƟ
ve
Humidity in ConĐƌete Slabs using in situ Probes. Any uneven areas greater than 3/16” in a 10 foot radius should be leveled with a
PortlandĐĞment based patĐhinŐĐompound. Holes andĐƌaĐŬs in theĐĞment should be paƚĐhed, and expansion joints should beĮlled
with a latex patĐhinŐĐompound. Newly pouredĐonĐƌete Ňoors must Đure for a minimum of 90 days.
Please note it is the person
installing theŇŽor and/or the homeowner’s responsibility to ensure a smooth substrate and that any moisture or alŬalinity issues
are resolved prior to installing theŇŽor. OnĐe installed, it beĐŽmes the installer’s responsibility.