Product Manual

it to the network.
3.
If Step 2 does not resolve the issue, we recommend installing a Z-Wave Repeater
nearby and performing a Z-Wave network rediscovery.
TIP: Any wall powered Z-Wave device will act as a Repeater and improve the range
between the Z-Wave Controller and the Z-Wave device you are installing.
Removing the Smart Water Valve+Meter from the Z-Wave network:
TIP: For best results, we recommend bringing the Z-Wave controller into the area where the Smart
Water Valve+Meter is installed.
1.
Put the Z-Wave controller in Remove mode. Refer to the controller documentation for
more information.
2.
Press the networking [Insert Radio Icon] button on the side of the Smart Water
Valve+Meter control unit to begin the remove process. The Nnetwork LED on the
control unit will begin flashing.
3.
After the Smart Water Valve+Meter is successfully removed from the Z-Wave
network, the Network LED on the Control Unit will turn off. If the Network LED is still
illuminated after the removal process, repeat Steps 1 and 2.
Resetting the Smart Water Valve+Meter to factory default settings:
Caution: Resetting the Smart Water Valve+Meter to its factory default settings will cause the
device to remove itself from the network and restore all settings to their default values.
1.
1. Press and hold the Networking [Insert Radio Icon] button for 15 seconds.
2.
All three LEDs will blink for five seconds and the device will restart.
3.
When the reset is complete, the LEDs will turn off and only the Valve Open or Valve
Closed LED will be illuminated.
Manual valve actuation:
In the event of power loss or system failure, the Smart Water Valve+Meter can be manually
actuated using the following procedure:
1.
Remove the actuator from the valve+meter by pulling the actuator away from the
valve+meter.
2.
Use a pair of pliers, adjustable crescent wrench or flat head screwdriver, to move the
valve stem to the correct position, as shown below.