Installation Guide

10 11
If the LEDs are blinking in a pattern, that means the
switches are configured incorrectly. Please double
check the wiring and switch positions before testing
the unit.
Test the operation of the Dry Contact Sensor by
placing the sump pump in alert state for approximately
two seconds. Make sure the Alert LED on the Dry
Contact Sensor turns on for 3 seconds. If the sensor
remains in the alert state, it will continue to blink for
5 minutes.
Add the sensor to the
Z-Wave newtork
Connect to the network using Z-Wave SmartStart
NOTE: An Alarm.com account is required for this process.
Power on and add devices one at a time.
Power on the Hub.
Log in to the MobileTech app and find the
customer account.
Add the device using SmartStart and follow the
on-screen instructions.
Scan the devices QR code found on the box or sensor.
Press the button on the sensor. (You will need to
remove the battery tab if you have not already done so.)
When the network LED on the sensor turns solid green,
the sensor has been successfully added.
Ensure you see the device on your account. This may
take up to 2 minutes.
Connect to the network manually
TIP: For best results, we recommend having the Hub in the same
room as the dry contact sensor you are adding.
Remove the battery tab from the sensor.
Put the Hub into Add mode. Refer to the Hub
documentation for more information.
Press the button on the sensor to add the
device to the network. When the network LED
on the sensor turns solid green, the sensor has
been successfully added.
Name the device based on its application.
This can be done on MobileTech, the Partner
Portal, or the Customer Website.