INSTALLATION 
Location Recommendations 
  Make sure the heat pump is not located where large amounts of water may enter the 
heater. This includes 
roof run-off
 and 
sprinklers
. 
  Re-direct any suspect sprinkler heads away from the heater. Use a deflector if 
necessary. (Corrosive sprinkler water damage will void the warranty!) 
  In cases where roof run-off is unavoidable, use of a down spout and/or gutters will 
protect the heater. 
  Make sure that the digital control does not face directly towards the sun.  Damage will not 
occur, but visibility in direct sunlight may be difficult.  
Clearances 
The Built Right pool heat pump is designed for outdoor installation only. Adequate air circulation 
is necessary for proper heat pump operation. Totally enclosed areas are not recommended. The 
heat pump should not be installed under a walkway or a porch. 
  At least 4 feet clearance should be allowed above the unit for unrestricted air discharge.  
  All sides of the heat pump require a minimum of 6 inches clearance from all walls or other 
air flow restrictions. 
  At least 24 inch access must be available for control panel.   
*These are manufacturer’s tested minimum values given. Where local and national codes apply, 
and values are different from those specified, use the greater value to ensure safe and proper 
installation. 
Equipment Pad 
Install the heat pump on a flat, slightly pitched surface, preferably a concrete or fabricated slab 
(pad). This allows proper drainage of condensation and rain water from the base of the unit. If 
possible, the pad should be placed at the same level or slightly higher than the filter system 
equipment pad. Slightly pitch the pad so that condensate run-off is directed away from the 
equipment pad. The base should be completely isolated from the building foundation wall to 
prevent the possibility of sound or vibration transmission into the building. The heater should be 
located as close as practical to the existing pool pump and filter to minimize water piping length.  
Condensation will occur from the evaporator coil while the unit is running and drain at a steady 
rate, usually 3 to 5 gallons per hour, depending upon ambient air temperature and humidity. The 
more humid the ambient conditions, the more condensation will be produced. The bottom of the 
unit acts as a tray to catch rainwater and condensation. 
Tie Down Straps 
The unit can be strapped down using the Built Right strap kit*. Attach a strap to each side and 
anchor to the deck. The Built Right strap kit may be used if local codes require securing the unit 
to the slab. *
The Built Right strap kit is available upon request.