Instructions

PX0587, PX0588, PX0597 & PX0587/SE Wiring Instructions
Recommended Cable types
Cable Construction Typical Cable Types
European: 10A - 3 x 1.0mm
2
H05VV-F, H05RR-F, H07RN-F
Nth American: 10A - 3 x 16AWG SJT, SVT
Earth/Ground
www.bulgin.co.uk
N
L
E
L
N
E
PX0587/SE PX0587 and PX0597
Before using the connector, it is important that these instructions are
carefully read and understood to ensure the connector is electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.
PX0587, PX0588, PX0597 and PX0587/SE Wiring Instructions
1 Remove cover.
2 Strip and prepare cable.
3 Thread cable sleeve along cable.
4 Connect wires to correct terminals:
Colour European Nth American
Live/Line (L) Brown Black
Neutral (N) Blue White
Earth/Ground ( ) Green/Yellow Green
5 Fit cable sleeve flange into slot adjacent to cable clamp.
6 Tighten cable clamp ensuring cable sheath is beyond cable
clamp. Reverse clamp to suit cable diameter.
7 Fit cover and tighten screw.
18mm
8mm
8mm
26mm (E)
30.0mm (L)
8mm
8
mm
18mm (N)
8mm
5
0mm (E)
PX0587/SE
PX0587, PX0588 and PX0597
N
L
E
PX0588
Earth/Ground