Datasheet

BUCCANEER FOR DATA
Standard Buccaneer - Ethernet
Sealing
Operating Temperature
Materials - Overmoulded
Overmould material
Flammability rating
Salt Mist
IP69K, Tested in accordance with
DIN 40050/Part 9 IP6k9k
IP68, EN60529:1992+A2:2013
(10m depth for 2 weeks)
–20°C to +70°C
PVC (black)
UL94V-0
EN60068-2-52 Test Kb Salt Mist
(Cyclic) Marine Severity Level 1
Connectors
Materials - Re-wireable and Panel Connectors
Connector body & locking ring
Panel connector
Flammability rating
‘O’ rings
Panel Gasket - round
Panel Gasket - ange
RoHS
Polyester
Nylon 6
UL94V-0
Silicone
Silicone
Neoprene
Compliant
Cable construction - PX0836, PX0837, PX0838 and 14199
Cables
Conductors
Insulation
Pair
Core
Screen
Braid
Sheath
Op Temperature
Diameter
Flame Test
Electrical @ 20°C
Characteristic:
Impedance
Capacitance
Conductor Loop
Resistance
Skew
TIA/EIA Rating
Mechanical Characteristics
Minimum Tensile Strength of Jacket (kgf/mm
2
)
Maximum Length for Strip of Jacket (mm)
24AWG (7/0.2mm) bare copper
HD-PE
2 of the above cores twisted
4 of the above cores
1 layer mylar and aluminium tape,
0.12mm tinned copper braid
PUR Jacket Black
–25°C to +85°C
6.1mm nominal
100 Ω ±15 Ω @ 100MHz
330pF/km
29/Ω100m maximum
45 nsec/100m @ 100MHz
Cat 5e
Polyurethane (PUR) Jacket
Braiding
7/0.12mm
Drain Wire
24 AWG
7/0.20mm conductor
Jacket
6.10mm dia
Cat 5e
26AWG (7/0.16mm) bare copper
PE (Skin - Foam - Skin)
2 of the above cores twisted
4 of the above cores
Aluminium & Polyester
Tinned Copper Braid
PVC Jacket Black
–25°C to +75°C
6.0 mm nominal
FT4
26Ω /km
Cat 6A
1.05
40
Cat 6a
Cable construction - PX0896, PX0897, PX0898 and 15241
Polyvinyl Chloride (PVC) Jacket
Braid Shield
Jacket
Twisted Pair
Aluminum Polyester
1P
1P
2P
2P
4P
4P
3P
3P
Mylar Tape
Insulation - HD - PE
Aluminium/ PEPT tape