User`s guide

5796, 7314-G30 42R4491 Power supply Un-Ex
For all other units,
SPCN cables
Power distribution card
This ends the procedure.
2. Is the reference code 1xxx2612, 1xxx9012, 1xxx9013, 1xxx90F0, 1xxx9135, or 1xxxC62E?
v No: Continue with the next step.
v Yes: The failing item is the SPCN frame-to-frame cable or adapter. The following list shows the
possible failing items, and the cable or adapter lengths when appropriate.
Use the following table to determine the part number for the field replaceable unit (FRU).
CCIN or FFC Type and model Part number Description Location code
1463 09P1251 SPCN cable (2
meters)
1464 22R5219 SPCN cable (6
meters)
1465 22R5221 SPCN cable (15
meters)
1466 22R5222 SPCN cable 30.0
meters
21F9360 SPCN cable 60.0
meters
0369 41U0128 SPCN optical cable
(100.0 meters)
1468 41U0129 Optical SPCN cable
(250 meters)
39J3865 SPCN optical adapter
This ends the procedure.
3. Is the reference code 1xxx2613?
v No: Continue with the next step.
v Yes: If there are two power supplies in the system, verify that both power supplies are plugged
into the same line voltage (either 110V ac or 220V ac, or -48V dc if your system is configured to
operate with this voltage). If this is not the case, correct it.
This error code can also be posted if the power supply cannot support the hardware in the
system. If there is only one power supply, and it is plugged into 110V ac, inform the customer that
the power supply must be plugged into 220V ac. If the customer does not have two power
supplies, the other option is to install the second power supply. This ends the procedure.
4. Is the reference code 1xxx5010?
v No: Continue with the next step.
v Yes: The firmware is reporting that the SPCN ports are not present. Replace the following FRUs
one at a time until the problem is resolved.
a. The cable from the SPCN ports on the back of the system (Un-P1-T3 and Un-P1-T4) to the
system backplane.
b. The system backplane at location Un-P1.
Use the following table to determine the part number for the field replaceable unit (FRU).
CCIN or FFC Type and model Part number Description Location code
Failing function codes, failing items, and symbolic FRUs 229