User`s guide

9-19
3. Pull the handle toward you.
4. Hold the handle and hard disk drive securely and pull it forward.
5. To use the server with the hard disk drive removed, insert a dummy tray into the empty slot.
IMPORTANT: To maintain the cooling effect in the server, install a dummy tray in the
vacant slot of the disk bay.
6. Close securely the door opened in step 1.
In a RAID System, the auto rebuild function can be used. The auto rebuild function can copy the information saved in a
defective hard disk drive into the newly replaced disk to recover the server as it was before the occurrence of the fault.
The auto rebuild function is valid for RAID System of RAID1, RAID5, or RAID6.
The auto rebuild starts automatically when hot-swapping a defective hard disk drive (or following a disk replacement in
the power-on state). During the auto rebuild, the disk lamp on the hard disk drive blinks alternatively green and amber.
IMPORTANT: If the auto rebuild fails, the disk lamp on the hard disk drive lights amber.
Reinstall the drive, and then run the auto rebuild.