Cautions and Limitations
A. Not for use in atmospheres containing less than 19.5%
oxygen.
B. Not for use in atmospheres immediately dangerous to life or
health.
C. Do not exceed maximum use concentrations established by
regulatory standards.
F. Do not use respirator if airflow is less than four cfm (115 lpm)
for tight fitting face pieces or six cfm
(170 lpm) for hoods and/or helmets.
H. Follow established cartridge and canister change schedules or
observe ESLI to ensure that cartridges and canisters are
replaced before breakthrough.
I. Contains electrical parts that may cause an ignition in
flammable or explosive atmospheres.
J. Failure to properly use and maintain this product could result
in injury or death.
K. The Occupational Safety and Health Administration regulations
require gas-proof goggles to be worn with this respirator when
used against formaldehyde.
L. Follow the manufacturer’s user instructions for changing
cartridges and/or filters.
M. All approved respirators shall be selected, fitted, used and
maintained in accordance with MSHA, OSHA and other
applicable regulations.
N. Never substitute, modify, add or omit parts. Use only exact
Bullard replacement parts in the configuration as specified by
the manufacturer.
O. Refer to User’s Instructions and/or maintenance manuals for
information on use and maintenance of these respirators.
P. NIOSH does not evaluate respirators for use as surgical
masks.
Use strictly in accordance with instructions, labels and
limitations pertaining to the PA30 respirator.
1. The PA30 respirator does not supply oxygen. Use only in
adequately ventilated areas containing at least 19.5%
oxygen.
2. Do not use when concentrations of contaminants are
immediately dangerous to life or health (IDLH). This term is
defined in 29CFR 1910.134 (b).
3. Do not use these respirators for respiratory protection
during abrasive blasting or clean up.
4. Do not use in circumstances where the airborne
concentration level of contaminant exceeds maximum use
concentration for this type of respirator as established by
regulatory standards.
5. Leave area immediately if:
• Breathing becomes difficult
• Dizziness or other distress occurs
You taste or smell the contaminant
• Unit becomes damaged
• Voltage alarm activates
6. This apparatus must not be worn with the blower unit
switched off. If the blower is switched off, a rapid build-up of
carbon dioxide and depletion of oxygen may occur, which
could result in death or serious injury.
7. Never alter or modify this respirator. Use only Bullard NIOSH
-approved PA30 components and replacement parts for this
respirator.
Failure to follow these warnings could result in death or serious
injury.
WARNING
Warnings and Limitations
1
PA3 - Powered Air-Purifying Respirator with High Efficiency (HE) Filters (2) – Approval No. TC-21C-0773
PA3 - Powered Air-Purifying Respirator with PA3NBC cartridges (3) for chlorine, hydrogen chlorine, sulfur dioxide, chlorine dioxide,
hydrogen fluoride, ammonia, methylamine, and particulates – Approval No. TC-23C-2236
PA3 - Powered Air-Purifying Respirator with OV-AG-HE Cartridges (3) for organic vapors, chlorine, hydrogen chloride, sulfur dioxide,
chlorine dioxide or hydrogen fluoride and particulates – Approval No. TC-23C-2237
PA3IS - Powered Air-Purifying Respirator with High Efficiency (HE) Filters (2) - Appproval No. TC-21C-0796
PA3IS - Powered Air-Purifying Respirator with OV-AG-HE Cartridges (3) for organic vapors, chlorine,
hydrogen chloride, sulfur dioxide, chlorine dioxide or hydrogen fluoride and particulates - Approval No. TC-23C-2307
PA3IS - Powered Air-Purifying Respirator with PA3NBC cartridges (3) for chlorine, hydrogen chlorine, sulfur dioxide, chlorine dioxide,
hydrogen fluoride, ammonia, methylamine, and particulates – Approval No. TC-23C-2306
www.bullard.com
* This warning applies to the PA3 PAPR Blower, the PA3IS PAPR Blower is Factory Mutual (FM) approved for
CLASS I DIV 1 Groups C, D
CLASS II DIV 1 Groups E, F, G
CLASS III DIV 1
Ta = -12ºC to 49ºC T4
*