Owner`s manual

3530
PROGRAMMING
Press and hold the and buttons at the same time on the trans-
mitter for 5 seconds, there will be a conrmation of (6) chirps with
(3) long chirps and the LED turns On for (2) seconds to conrm the
system, Feature Programming all returns to factory default setting.
SHUTDOWN DIAGNOSTICS:
The unit has the ability to report the cause of the last shutdown of the
remote start system.
Turn the Ignition switch to “ON” position.
Press the button on the transmitter.
The LED will now report the last system shutdown by ashing for (1)
minute in the following grouped patterns:
LED
Flashes Shutdown Mode
1 (-) Safety Shutdown
Input (Hood)
1. Close the Hood
2. Check GREY wire connection
2 (+) Safety Shutdown input
(Brake) or Neutral Safety
Switch input fail
1. Check BROWN/RED wire
connection
3. Move the Enable Toggle Switch to
“ON” position. (If installed)
4. Move the gear selector to “PARK”
/ “NEUTRAL” position.
5. Check THIN BLACK wire
connection.
3 No RPM (Engine Checking TACH)
or Hi Voltage. (Engine Checking
voltage.)
Check VIOLET/WHITE wire
connection
Program the “CHECK LEVEL” from
“Hi Check Level” to “Low Check Level”
5 Over-rev
6 System timed out
7 Transmitter
8 Tach Signal has not
been learned
Re-learning the RPM
(Feature IV - 2)
3.
1.
2.
3.
TESTING YOUR INSTALLATION
Note: A second IN4003 series diode may be required to maintain the
integrity of the hood open, shut down circuit. If this is the case, it must be
installed as shown in the diagram above. The anode (Non Stripped) side
must be connected to the GREY (H4/4) wire of the remote start unit.
The cathode (Striped) side must be connected to the hood pin switch.
METHOD 2
To connect to the key in sensor circuit as shown for method 2:
Locate the control wire that connects the driver’s door pin switch
to the key in sensor switch.
Cut this wire and connect the ignition cylinder side to chassis
ground.
Locate the key in sensor switch wire that connects the chime mod-
ule to the ignition cylinder.
Cut this wire and connect the ignition cylinder side to the Remote
Start Negative Safety Shut down wire GREY (H4/4), using an
IN4003 series diode as shown above.
Note: A second 4003 series diode may be required to maintain the in-
tegrity of the hood open, shut down circuit. If this is the case, it must be
installed as shown in the diagram above. The anode (Non-striped) side
must be connected to the GREY (H4/4) wire of the remote start unit.
The cathode (Striped) side must be connected to the hood pin switch.
AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE
AS INDICATED IN ANY OF THE PREVIOUS ALTERNATE CONFIGU-
RATIONS, THIS CIRCUIT MUST BE TESTED FOR OPERATION.
Retest by following the steps outlined in the NEUTRAL START SAFETY
TEST shown in this manual.
A.
B.
C.
D.