Use and Care Manual

INSPECTING / CLEANING BURNERS AND GAS
VALVE ORIFICES
(CONT.)
BURNER REPLACEMENT INTO INSERT
CAUTION – Always turn off the gas supply prior to clearing your grill.
1. Replace burner back into the grill insert. There is no need to replace the cotter pin back into the cast peg, it is for shipping purposes only.
2. Check the burner for proper location after replacing. Make sure the valve orifices are inside of the burner tubes (see drawing below). If the
valve orifices do not fit inside the burner tubes, lighting the burners may cause explosion and/or fire.
IGNITOR I ELECTRODE CHECK
With all control knobs set to “OFF”, check each igniter individually for presence of spark at electrode. In turn, push each control knob in fully and
turn slowly about a 1/4 turn to the left (counter-clockwise) until a click is heard; the trigger hitting the strike block should produce a blue spark at the
electrode tip. Return control knob to “OFF” before checking next igniter.
BURNER OPERATION CHECK
NOTE: Upon first assembly the gas lines and burners will be full of air. In order for the burners to light properly the lines must fill with gas. It may
require several attempts at lighting the burners before you are successful.
1. With BBQ Grill control knobs in “OFF” position, turn on the Gas supply.
9