Use and Care Manual

INSTALLATION INSTRUCTIONS
Your single sideburner comes to you fully assembled. We strongly recommend professional installation and hookup of the single sideburner. These
instructions will provide you with the measurements necessary for you or your builder to construct a masonry structure to house your outdoor
single sideburner.
NOTE TO INSTALLER: Leave these instructions with the consumer for future reference. The single sideburner must be installed in accordance
with all local building codes.
SPECIFICATIONS FOR SINGLE SIDEBURNER STRUCTURE
1. Your choice of masonry can be used for cabinet construction for the single sideburner; however it must be non-combustible material. Keep in
mind when choosing a location for your sideburner that it should NOT be located under any overhead combustible construction. Upper and ground
level vents must be provided for combustion air on both sides of built-in cabinet. The single sideburner insert must remain unobstructed to allow for
combustion air and ventilation.
2. The single sideburner requires a wall opening of the following dimensions: See PAGES 6 & 7 for different models.
3. Place single sideburner assembly into wall opening as shown in illustration on pages 6 & 7. The single sideburner rests on the front, back and
side edges of the insert.
4. For propane gas LP TANK STORAGE AREA MUST BE ISOLATED FROM SINGLE SIDEBURNER AND VENTED.
5. Do not use any combustible materials for this construction. Minimum horizontal clearance to adjacent combustible surface from side and back of
the single sideburner must be 21 inches. A 6 inch clearance is required behind the sideburner to allow for ventilation purposes.
CONNECTING TO GAS SOURCE
Refer to the following instructions and illustrations for typical gas supply connections. We strongly suggest professional installation and hook-up of
the single sideburner.
IMPORTANT: Before connecting single sideburner to gas source,
make sure the sideburner control knob is in the “OFF” position.
5
NATURAL GAS CONNECTIONS
IMPORTANT: Bull Outdoor Products does not recommend the use of
any quick connect fittings or lines to the unit. Use of these types of
fittings or lines could cause low gas flow and greatly reduce the
performance of the unit.
- Pipe sealing compound or pipe thread tape of the type resistant to the
action of natural gas must be used on all male pipe thread.
- Apply compound or tape to at least the first three threads when making
the connection.
- Attached the other end of flex line to shut-off valve through a nipple.
- Attach a shut-off valve to gas supply pipe.
PERFORM GAS LEAK CHECK REFER TO PAGE 2
PROPANE GAS CONNECTIONS
- The LP gas hose supplied with this unit must be used without alteration. If this hose
needs to be replaced, use only the type 1 specified in the parts list supplied with this unit.
Use a LP tank with a type 1 cylinder valve.
- Make sure the tank is firmly secured in an upright position.
- Turn the black coupling nut of the hose and regulator assembly in a clockwise direction.
- Make sure it is completely threaded onto the cylinder valve before turning gas supply on.
PERFORM GAS LEAK CHECK REFER TO PAGE 2
READ CAREFULLY BEFORE ASSEMBLY AND OPERATION OF YOUR SINGLE SIDEBURNER