STANDARD CONTROL SYSTEM
MASTER CONTROL PAD (Figures J/K)
Temp Set (80°F - 104°F)
The start-up temperature is set at 100°F. The last meas-
ured temperature is constantly displayed on the LED.
Note that the last measured spa temperature dis-
played is current only when pump 1 (“Jets 1” )has
been running for at least 2 minutes.
Press the “Temp Set” button to display and adjust the
set temperature. After three seconds, the LED will
automatically display the last measured temperature.
Jets 1
Touch the “Jets 1” button once to activate the low speed
of pump 1 and again for the high speed. Press the “Jets
1” button again to turn off pump 1. If left running, the
pump’s low speed will automatically turn off after 2
hours, and the pump’s high speed will automatically
turn off after 30 minutes. The pump’s low speed runs
when the spa is heating, when a filter cycle is activated,
or when a freezing condition is detected. If the pump’s
low speed is on under Automatic Spa Control, it can
only be deactivated by entering the Standby Mode.
Jets 2
Touch the “Jets 2” button once to activate the low speed
of pump 2 and again for the high speed. Press the “Jets
2” button again to turn off pump 2. If left running, the
pump’s low and high speeds will automatically turn off
after 30 minutes.
Note: Either pump can also be activated by an optional
auxiliary control button (if installed) (Fig. K1)
Light
Press the “Light” button to turn the light on and off. If
left on, the light automatically turns off after 4 hours.
Modes
Press “Temp Set”, then “Jets 2” (or “Aux”) to switch
between Standard, Economy, and Sleep Modes.
Standard Mode is programmed to maintain the desired
temperature. Note: the last measured spa temperature
displayed is current only when pump 1 has been run-
ning for at least 2 minutes. “St” will be displayed
momentarily when you switch into standard mode.
Economy Mode heats the spa to the set temperature
only during filter cycles. “Ec” will display solid when
temperature is not current, and will alternate with tem-
perature when temperature is current.
Push “Jets 1” to shift to Standard-in-Economy Mode,
indicated by “SE” alternating with the temperature. The
spa operates the same as it does in Standard Mode, but
reverts to Economy Mode automatically after 2 hours.
During this time, a press of the “Mode” button will
revert to Economy Mode immediately.
Note: Heating will occur more quickly in Standard-in-
Economy Mode if a low-speed (versus a high speed)
(Figure J) Standard Control Pad
(Figure K) Standard+ Control Pad
1
2