Owner`s manual

Page 39 Bullfrog Spas Owner’s Manual
of the filter/skimmer cavity.
PROBLEM: Jets are weaker than normal or do not
work at all, but in both cases the pump is running.
Cause: 1. Jet handle(s) is partially or fully closed.
Solution: Open jet handle(s).
Cause: 2. Spa filter cartridge is dirty.
Solution: See "Cleaning Your Filter" in this Owner's
Manual.
Cause: 3. There is air trapped in the spa equipment or
its face piping.
Solution: Open the air-bleed valve on each pump
housing and allow air to bleed out of system. Be sure
to tighten each air-bleed valve as soon as water starts
to flow out.
Cause: 4. The Suction Fitting(s) are blocked.
Solution: Remove any item or debris that is blocking
each Suction Fitting.
Cause: 5. The JetZone Divider is not installed (This
only applies to spas that have two pumps).
Solution: Re-install in the appropriate JetPak position.
(Warning: Running your spa without a JetZone Divider
can cause serious damage to your pump.)
Cause: 6. Slice Valve is closed.
Solution: Open Valve and secure with Valve Keeper.