Owner`s manual

25
• Standard Mode (Std): maintains the desired temperature of
the spa. Std will appear on the display momentarily when
you switch into Standard mode.
• Economy Mode (Ecn): heats the spa to the set temperature
only during lter cycles. Ecn will appear solid in the display
when the spa is heating and will ash intermittently when
the spa is not heating. Press jets 1 while in Economy mode
to place the spa in Standard-In-Economy mode (SE), which
operates the same as Standard mode, however; it will revert
to Economy mode automatically after 1 hour.
• Sleep Mode (SLP): heats the spa to within 20
F (11
C) of the
set temperature only during lter cycles. SLP will appear on
the display until the mode is changed.
Standby Mode (Sby)
Standby Mode idles all of the spa’s functions. This is helpful
when changing a lter or a JetPak. Press temp then jets 2 or
aux to start mode. Press any button to exit this mode.
Jets 1
Press jets 1 to turn pump 1 on and off and to shift between
low and high speeds. If left running, the low speed will turn off
after 4 hours and the high speed will turn off after 30 minutes.
When the low speed turns on automatically, it cannot be
turned off from the control panel.
NOTE: When in standard mode, the low speed of pump 1 may
activate for at least 2 minutes every 30 minutes to detect the
spa temperature and will heat to set temperature (if
needed).
Jets 2 (optional)
With a two pump system, press jets 2 to turn pump 2 on or off
and to shift between low and high speeds. If left running, the
pump will turn off automatically after 15 minutes. NOTE: If the
spa does not have two pumps, the jets 2 button will be
labeled aux.
Auxiliary Jet(s) Control
An optional auxiliary control pad(s)
on the side of the spa can also
activate the pump(s). NOTE: This
option is not available on Tadpole
Hot Tub models.
Light
Press light to toggle the light on and off.
The light will turn off automatically after 4 hours.
LED Light (optional)
Press light to toggle the LED light on and off. Press light + light
to shift through the color options. The light will turn off
automatically after 4 hours.
Preset Filter Cycles
The pump and ozone purier* will run during ltration. At the
start of each lter cycle, pump 2 will run for 5 minutes to clean
out the JetPaks
and JetPods
associated with pump 2.
There are two lter cycles per day. The rst lter cycle begins 6
minutes after the spa is powered up. The secondlter cycle
begins 12 hours later. Filter duration is programmable for 1-12
hours (F1-F12). The default lter time is 2 hours per cycle.
To program, press temp + jets 1. Press temp to select thelter
duration. Press jets 1 to select the number of lter cycles. The
display will show dn (day and night), d (day only), or n (night
only). Press temp to adjust. Press jets 1 to exit the program. For
continuous ltration, use F12 and dn. NOTE: Allowing the lter
pump to operate for extended periods of time with the cover
on the spa will result in a rise of the spa water temperature.
During warmer months of the year, it is advisable to set the
duration of the ltration cycle to the minimum level needed
to keep the water clean.
Freeze Protection
If the temperature drops to 44
F (7
C) within the heater, the
pump automatically activates to provide freeze protection.
The pump will stay on 4 minutes after the sensor has detected
the temperature has reached 45
F (7
C) or higher.
Cleanup Cycle (optional)
A cleanup cycle begins 30 minutes after the pump is turned
off or times out. The pump and ozone purier* will run for 1
hour. NOTE: To activate this feature, contact your authorized
Bullfrog Spa dealer.
*Ozone Purier (optional)
The ozone purier runs duringlter cycles (except when pump
1 is operating on high speed or when pump 2 is running on
any speed) and during clean-up cycles.
Operation