Owner`s manual
26
Premier Control System (Bullfrog Spa models only)
General
The pump responsible for heating and ltration is pump 1.
Timeouts refer to a preset length of time that a function is
programmed to operate before shutting off automatically.
Certain conditions (lter or freeze) can cause a function
to operate longer, while faults can cause a function to
operate for a shorter length of time. The system keeps track
of timeouts regardless of other conditions. NOTE: In multi-
button sequences (shown by the + sign), if subsequent
buttons are pressed too quickly the desired result may not
occur.
Initial Startup
Before turning on the power to the spa, make sure the spa is
properly lled with water and the equipment door has been
secured. When your spa is rst actuated, it will begin the
Priming mode. The Priming mode will last for up to 4 minutes,
and then the control system will begin to heat the spa and
maintain the water temperature in the Standard mode. Press
warmer or cooler to exit the Priming mode early.
Icon Legend
Heat Icon - Indicates different stages of
heating.
Jets Icon - Spins fast on high speed/spins
slow on low speed
Light Icon
Setting the Time
Once the spa has been properly connected the TIME icon
will appear on the control panel’s liquid crystal display (LCD).
Press time + mode/prog. Select the hour by pressing warmer
or cooler. (Each press changes the time by 1 hour.) Press
mode/prog to switch to minutes. Select minutes by pressing
warmer or cooler. (Each press changes the time by 1 minute.)
Press time to conrm. Press mode/prog to exit the time setting
procedure and enter the optional lter cycle programming.
Press mode/prog to exit programming.
NOTE: Time settings are not preserved in the event of a power
loss.
Filter Cycles
NOTE: At the start of each lter cycle, the lowest speed of
pump 2 will run for 5 minutes to clean out the JetPaks
™
and
JetPods
™
associated with pump 2. NOTE: Allowing the lter
pump to operate for extended periods of time with the cover
on the spa will result in a rise of the spa water temperature.
During warmer months of the year, it is advisable to set the
duration of the ltration cycle to the minimum level needed
to keep the water clean. NOTE: The pump and ozone purier*
will run during ltration.
Preset Filter Cycles: Your spa came programmed from the
factory with these defaults. There are two lter cycles per
day. The rst lter cycle will automatically activate at 8:00
a.m. and will operate for 2 hours. The second lter cycle will
automatically activate at 8:00 p.m. and will operate for 2
hours. The start and end times of the lter cycles are
programmable. To program, set time as instructed in Setting
the Time and follow the instructions in Custom Filter Cycles.
Custom Filter Cycles: To program custom lter cycle
settings, press time + mode/prog + mode/prog + mode/prog
within 3 seconds. The PROGRAM, FILTER 1, and START TIME
icons will appear on the display. Press warmer or cooler to
choose the lter start time hour. Press mode/prog to enter the
hour. Press warmer or cooler to choose the lter start time
minutes. Each press changes the start time by 5 minutes. Press
mode/prog to enter the minutes. Press mode/prog to see the
PROGRAM, FILTER 1, and END TIME icons. Adjust the time as
done above. Press mode/prog to see the PROGRAM, FILTER 2,
and START TIME icons. Proceed as above. Press mode/prog to
see PROGRAM, FILTER 2, and END TIME icons. Adjust the time
as previously stated. Press mode/prog to enter the new lter
cycle times into the system and display the current water
temperature. Press time at any time during this programming
sequence to save the values entered up to that point and
exit programming.
timetime
F1F1
F2F2
PLPL
TLTL
jets 1jets 1
jets 2jets 2
mode/progmode/prog coolercooler
warmerwarmer
lightlight
optionoption
TM
timetime
F1F1
F2F2
PLPL
TLTL
jets 1jets 1
auxaux
mode/progmode/prog coole rcooler
warmerwarmer
lightlig ht
optionoption
TM
Operation
Premier Control System One Pump
Premier Control System Two Pumps