Owner`s manual

Standby Mode (Sby): helpful when changing a filter or a Jetpak. Press TEMP followed by
LIGHT to start mode, to exit this mode press any button.
Sleep Mode (SLP): heats the spa to within 20 °F (11 °C) of the set temperature during filter
cycles only.
Jets 1
Press JETS 1 to turn pump 1 on or off and to shift between low and high speeds. The low speed will turn
off after 2 hours and the high speed will turn off after 15 minutes.
Low speed of pump 1 may activate for at least 2 minutes every 30 minutes to detect the spa temperature
(polling) and will heat to set temperature if needed. When the low speed turns on automatically, it cannot
be turned off from the control panel.
Jets 2
Press JETS 2 to turn pump 2 on or off and to shift between low and high speeds (if a two
pump system). If left running, the pump will turn off automatically after 15 minutes.
Note: An optional auxiliary control button on the side of the spa can activate either pump.
Light
Press LIGHT to turn the light on or off. The light will turn off automatically after 4 hours.
LED Light (optional)
Press LIGHT to turn on light. Press LIGHT again to shift through color options. The light will turn off automatically
after 4 hours.
Preset Filter Cycles
Press TEMP then JETS 1. Press TEMP to select the filter duration. Press JETS 1 to select the number
of filter cycles. The display will show dn (day and night), d (day only), or n (night only). Press TEMP to
adjust. Press JETS 1 to exit the program.
The pump and ozone generator* will run during filtration. At the start of each cycle, the blower will run on
highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 will run for 5
minutes. The first filter cycle begins 6 minutes after the spa is powered up. The second filter cycle
begins 12 hours later. Filter duration is programmable for 1-12 hours. The default filter time is 2 hours.
Freeze Protection
If the temperature drops to 44°F (6.7°C) within the heater, the pump automatically activates to provide
freeze protection. The pump will stay on 4 minutes after the sensor has detected the temperature has
reach 45°F (7.2°C) or higher.
Clean-Up cycle (optional)
A clean-up cycle begins 30 minutes after the pump is turned off or times out. The pump and ozone
generator* will run for 1 hour.
*Ozone Generator (optional)
The ozone generator runs during filter cycles (except when pump 1 is operating on high speed) and
during clean-up cycles.
Bullfrog Spas Owner’s Manual