Troubleshooting guide
11
A Series Spas- A900
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and jets in
the plumbing system before lling to allow as much air as possible to escape
from the plumbing and the control system during the lling process. After
turning the power on at the main power panel, the top-side panel will display
a splash, or startup screen.
Priming Mode
After the initial start-up sequence, the control will enter Priming Mode and
display a Priming Mode screen. Only pump icons appear on the priming mode
screen. e system will automatically return to normal heating and ltering at
the end of priming mode, which lasts 4-5 minutes. During the priming mode,
the heater is disabled to allow the priming process to be completed without
the possibility of energizing the heater under low-ow or no-ow conditions.
Nothing comes on automatically, but the pump(s) can be energized by select-
ing the “Jets” buttons. If the spa has a Circ. Pump, it can be turned on and
o by pressing the “Circ Pump” button during Priming Mode. Manually exit
Priming Mode by pressing the “Exit” button.
Priming the Pumps
As soon as the Priming Mode screen ap-
pears on the panel, select the “Jets 1” button
once to start Pump 1 in low-speed and
then again to switch to high-speed. Also,
select the other pumps, to turn them on.
e pumps should be running in high-
speed to facilitate priming. If the pumps
have not primed after 2 minutes, and water
is not owing from the jets into the spa,
do not allow the pumps to continue to run.
Turn o the pumps and repeat the process.
NOTE: Turning the power o and back on again will initiate a new pump
priming session. Sometimes momentarily turning the pump o and on will
help it to prime. Do not do this more than 5 times. If the pump(s) will not
prime, shut o the power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more
than 2 minutes. Under NO circumstances should a pump be allowed to run
without priming beyond the end of the 4-5 minute priming mode. Doing so
may cause damage to the pump and cause the system to energize the heater
and go into an overheat condition.
mê á ã áåÖ=j çÇÉ
Exit Jets 1 Jets 2Circ
Fill it up!
Priming Mode