Troubleshooting guide

29
INFO (System Information sub-menu)
e System Information Menu displays various settings and identi cation of
the particular system. As each item in the menu is highlighted, the detail for
that item is displayed at the bottom of the screen.
SSID (Software ID)
Displays the software ID number for the System.
MODL (System Model)
Displays the Model Number of the System.
SETP (Current Setup)
Displays the currently selected Con guration Setup Number.
SIG (Con guration Signature)
Displays the checksum for the system con guration  le.
Heater Voltage
Displays the operating voltage con gured for the heater.
H _ (Heater Type)
Displays a heater type ID number.
SW _ (Dip Switch Settings)
Displays a number that represents the DIP switch positions of S1 on the
main circuit board.
PANL (Panel Version)
Displays a number of the software in the topside control panel.
Utilities and Information
Utilities
In addition to INFO, e Utilities Menu contains the following:
GFCI (GFCI Test)
(Feature not available on CE rated systems.)
GFCI Test is not always enabled, so it may not appear. is screen allows
the GFCI to be tested manually from the panel and can be used to reset the
automatic test feature. If the GFCI Test Feature is reset, the device will trip
within 7 days. (SeePage 31)
A / B (A/B Sensor Temperatures)
When this is set to On, the temperature display will alternate to display
temperature from Sensor A and Sensor B in the heater.
FALT LOG (Fault Log)
e Fault Log is a record of the last 24 faults that can be reviewed by a
service tech.
Additional Utilities