Troubleshooting guide
33
Step 1: Put the spa in “Hold”, this will prevent the pump(s) from activating
(see Control Systems).
Step 2: Remove the head rest and Snap-Cap by lifting upwards.
CAUTION! WHILE PERFORMING STEPS 3&4 YOU MUST USE
THE BLACK MANIFOLD AREA AS THE POINT OF CONTACT AS
SHOWN IN THE PICTURE. PRESSURE APPLIED TO THE FRONT
FACE (ACRYLIC PLATE) MAY CAUSE DAMAGE TO THE JETPAK
VOIDING THE WARRANTY
Step 3: While applying pressure downward on the manifold push the mani-
fold away from you toward the inside of the spa to release the manifold from
the wall clip assembly, then lift the plate straight up to remove.
Step 4: Exchange JetPak
Step 5: Lower the manifold of the new JetPak carefully as to align the lower
valve assembly and gasket into the bulkhead tting. Apply pressure downward
as you pull the JetPak manifold toward you to until the manifold is secured in
the wall clip assembly .
Step 6: Reattach the Snap-Cap and head rest.
Interchanging JetPaks- A & R Series
JETPAKS