Troubleshooting guide
3
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Safety Instructions
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
1. Read and follow all instructions:
2. WARNING: To reduce the risk of injury, do not permit children to
use this product unless closely supervised at all times.
3. As per UL requirements (U.S.), a wire connector is provided on this unit
to connect a minimum No. 8 AWG (8.4mm2) solid copper conductor
between this unit and any metal equipment, metal enclosures of electrical
equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
4. WARNING: For products provided with a cord-connected,
ground-fault circuit-interrupter, the GFCI must be tested before each
use. If the GFCI fails to operate properly, disconnect the power until the
fault has been identied and corrected.
5. DANGER: Risk of Accidental Drowning. Extreme caution must be
exercised to prevent unauthorized access by children. To avoid accidents,
ensure that children cannot use this spa unless they are supervised at all times.
6. DANGER: Risk of Injury. e suction ttings in the spa are sized to
match the specic water ow created by the pump. Should the need arise
to replace the suction ttings or the pump, be sure that the ow rates are
compatible. Never operate the spa if the suction ttings are broken or
missing. Do not replace a suction tting with one rated less than the
ow rate marked on the original suction tting.
7. DANGER: Risk of Electric Shock. As per UL requirements (U.S.),
install spa at least 5 feet (1.5m) from all metal surfaces. A spa may be
installed within 5 feet (1.5m) of metal surfaces if each metal surface is
permanently connected by a minimum of No. 8 AWG (8.4mm2) solid
copper conductor to the wire connector on the terminal box that is
provided for this purpose.
8. DANGER: Risk of Electric Shock. Do not permit any electrical
appliances, such as a light, telephone, radio, or television within 5 feet
(1.5m) of the spa. ese units DO NOT have an integral ground fault
circuit interrupter. e installation of an integral ground fault circuit
interrupter MUST be completed by a qualied Electrician and must
meet all applicable electrical codes.
9. For Cord-Connected units:
a. Replace damaged cord immediately.
b. Do not bury cord.
c. Connect to grounded, grounding-type receptacle only.
10. WARNING: To Reduce the Risk of Injury:
a. Water temperature in a spa should never exceed 104˚F (40 ˚ C). Water
temperatures between 100˚ F (38˚C) and 104˚F (40˚C) are considered
safe for a healthy adult. Water temperature in excess of 104˚ F (40˚ C)
may be harmful to your health. Lower temperatures are recommended
for young children and/or when spa use exceeds 10 minutes.
b. High temperatures could have a potential for causing fetal damage
during pregnancy. Pregnant women or women that could be pregnant
should consult a physician and possibly limit spa usage when tempera-
tures are in excess of 100˚ F (38˚ C).