12V Maximum on Live Parts: Live parts accessible to the user must not
exceed 12V.
240V~/60Hz 30A Conversion Option: If there is not 50A of electrical
service available, an authorized Bullfrog Spa dealer or Electrician can easily
convert the spa to operate on 30A (conversion instructions are located inside
the Control System Box). Please be aware, spas converted to 30A are only
capable of heating the water when pump 1 is in low-speed, not high-speed.
is heating limitation is acceptable in most climates as well as indoor instal-
lations.
230V~/50Hz, 32A Conversion Options: If there is not 32A of electrical
service available, an authorized Bullfrog Spa dealer or an Electrician can
easily convert the spa to operate on either a single or dual 16A x2 service.
Conversion instructions for the following congurations are located inside
the Control System Box of the spa.
230V~/50Hz 16A Single Service: Please be aware, spas converted to 16A are
only capable of heating the water when the circulation pump is in low-speed,
not high-speed. is heating limitation is acceptable in most climates as well
as indoor installations.
230V~/50Hz 16A, 16A Dual Service: Operation of spa is identical to single
32A service except that service is divided into two separate 16A services.
400V~3N 16A x 3, 50Hz Service: Operation of spa is identical to 32A ser-
vice is divided into 3 separate 240V~ service with one shared neutral.
New Installations and Re-Installations: ese instructions apply to both
new installations and re-installations which may occur when a spa is moved
or relocated to a new location.
120V~/60Hz Equipment
120V~/60Hz Cord- Connected Installation: is option is only applicable
if the spa was ordered from the factory with both a 120V~/60Hz pump and a
120V~/60Hz power cord. e spa’s Safety Approval Listing and warranty will
be void, and the spa may be unsafe if an aftermarket power cord is installed
on the spa. Cord-Connected spas have already been converted to operate on
120V~/60Hz power at the factory and come with approximately 15‘ (4.57m)
of useable power cord (the maximum length allowed) attached to the spa.
is factory installed power cord comes with a built-in GFCI breaker.
IMPORTANT: Cordage shall be replaced only with a special cordage
assembly available from the manufacturer, its service agent, or similarly quali-
ed persons in order to avoid a hazard.
Cord-Connected 120V~/60Hz spas require that the factory installed power
cord, with its built-in GFCI breaker be connected to a 120V~/60Hz, 15A,
Single-Phase, dedicated, grounded circuit and power outlet. It is important
that this circuit is dedicated (not being used by any other electrical appliance)
or your spa may not function properly. For safety purposes, the location of the
power outlet (where the spa is to be connected) can be no closer than the mini-
mum allowable distance specied by the national and local wiring rules in your
area. Installation must be in accordance with all national and local wiring rules.
WARNING: Never use an extension cord. Bullfrog International, LC
does not allow the use of an extension cord under any possible situation.
e use of an extension cord voids any warranty on the spa equipment and
also exposes the consumer to additional risk of re, electrical shock, injury,
or death.