Troubleshooting guide
61
Template 40981_C 02-17-10
56340-01_97_A 01-26-13
5
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
Settings
Hardware Setup
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF SWITCHBANK S1 ON
PART B
BFBP20 – PN 56340-01
01-24-13
USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE
TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA
A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM
THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE
INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.
CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.
FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF
60°C AMPACITY BUT RATED MINIMUM OF 90°C.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS. (31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE.
#6 AWG MIN. WIRE = 90°
1 PROGRAMMABLE FILTRATION + POLLING 2-SPEED 2-SPEED °F
2 2-SPEED 2-SPEED °F
3 PROGRAMMABLE FILTRATION + POLLING 2-SPEED °F
4 2-SPEED °F
SETUP # CIRC PUMP PUMP 1 PUMP 2 TEMP SCALE
SYSTEM WILL BE IN
SETUP #2
UNLESS MARKED
DIFFERENTLY
BELOW
INSTEAD OF
SETUP #2,
THIS SYSTEM IS
CONFIGURED IN
SETUP #:
PUMP 1 LOW TIMEOUT IS 60 MINUTES.
PUMP 2 IS USED IN SETUPS 1 & 2 ONLY
LOCATION DEVICE VOLTS MAX AMPS FROM TO
J9 2-SP PUMP 1 240V 12A MAX J46 J72-GROUP 2
J14 2-SP PUMP 2 240V 12A MAX J18 J3-GROUP 2
PUMP 2 LINE 1 CONNECTION J19 J43
J15 SPA LIGHT 12V 1A
J21 CIRC PUMP 120V 2A MAX J20 J79-GROUP 4
J32 UNUSED
CIRC PUMP LINE 1 CONNECTION J81 J59
J33 TV / AV 120V 3A J38 J45-GROUP 4
J44 HEATER 240V 4.0 kW
J6 & J7 CABINET LED 12V 0.1A
LOCATION DEVICE VOLTS MAX AMPS
J6 ON OZONE 120V 2A MAX
EXPANDER
BOARD X-B
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A
STORE SETTINGS*
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE A
MEMORY RESET*
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
Settings