Troubleshooting guide

65
Settings
Template 40981_C 02-17-10
56342_97_A 11-28-12
5
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2012 Balboa Water Group.
Settings
Hardware Setup
PART B
BFBP21 – PN 56342
11-28-12
LOCATION DEVICE
J9 NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1
J14 NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 2 ALIMENTATION POMPE 2 A 2 VITESSES 2-SPEED PUMP 2
PUMP 2 LINE 1 CONNECTION J19 to J43
J15 10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
J21 KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
CIRC AND OZONE LINE 1 CONNECTION J81 to J59
J32 N/A
J33 TV / AV
J40 IR RECIEVER
J5, J8 AUX PANEL(S) - AX10, AX20, AX30, AX40
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF SWITCHBANK S1 ON
230V 3þ / 3x16A
230V 2þ / 2x16A
GRN
BLU
1 BRN
2 BRN
3 BRN
CIRC PUMP OPTION
PROGRAMMABLE FILTRATION CYCLES +
POLLING
USED IN SETUPS 1 & 3
SINGLE SERVICE 230V 1þ / 1x32A, TWO-SERVICE 230V 1þ / 2x16A, THREE-SERVICE 230V 1þ / 3x16A
230V 1þ
1x32A
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A*
STORE SETTINGS**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
**SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
SYSTEM WILL BE SHIPPED IN SETUP #1
UNLESS MARKED OTHERWISE
INSTEAD OF SETUP #1,
THIS SYSTEM IS CONFIGURED IN SETUP #:
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
TORQUE RANGE FOR
MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS.
(31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
TB1
1
2
3
4
4
3
2
1
J78
J45
J79
J72
J42
J3
J37
J4
J1
J61J47
J54
J77
J75
J36
J60
J53 J58
J41
J12
J88
J62
J51
J52
J98
GRN
1 BLU
2 BRN
1 BRN
2 BLU
TB1
1
2
3
4
4
3
2
1
J78
J45
J79
J72
J42
J3
J37
J4
J1
J61J47
J54
J77
J75
J36
J60
J53 J58
J41
J12
J88
J62
J51
J52
J98
J38
J20
J18
J18
J38
J20
J46
J46
1 PROGRAMMABLE FILTRATION + POLLING 2-SPEED 2-SPEED °C
2 2-SPEED 2-SPEED °C
3 PROGRAMMABLE FILTRATION + POLLING 2-SPEED °C
4 2-SPEED °C
SETUP # CIRC PUMP PUMP 1 PUMP 2 TEMP SCALE
SYSTEM WILL BE IN
SETUP #1
UNLESS MARKED
DIFFERENTLY
BELOW
PUMP 1 LOW TIMEOUT IS 60 MINUTES.
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B*
MEMORY RESET**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
230V 1þ 1X16A
230V 2þ
2X16A
A2
A3
A4
OFF ON
230V 3þ 3X16A
A2
A3
A4
OFF ON