SERVICE (cont.)
Dispense Valve (PC & H3 Element Only)
Location:
The Dispense Valve is located behind control panel.
Test Procedures:
1. Check the valve for coil action. Turn on the valve with
the dispense button. Listen carefully in the vicinity
of the dispense valve for a click as the coil pulls the
plunger in.
If no sound is heard as described, proceed to #2.
If the sound is heard as described, there may be a
blockage in the valve. Disconnect the dispenser from
the power source. Remove the valve and inspect for
blockage, and de-lime all related areas.
2. Connect voltmeter leads to the coil terminals. Turn
on the valve with the dispense button. Set the meter
to AC volts. The indication should be line voltage
when activated.
If voltage is present as described, but no coil action
is observed, valve is defective. Replace valve and test
again to verify repair.
If voltage is not present as described, refer to Wiring
Diagrams and check the dispenser wiring harness. Also
check the control board for proper operation.
FIG. 19a DISPENSE VALVE
Removal and Replacement:
1. Disconnect the dispenser from the power source
and allow to cool.
2. Drain enough water from the tank so the water level
is below the outlet.
3. Remove the top cover (3 screws) and front shroud
(4 screws).
4. Loosen snap clamp and remove silicon dispense
nozzle.
5. Remove the two screws securing the valve.
6. Disconnect wires from the valve.
7. Pull the valve straight out of its grommet.
8. Install new valve into grommet.
9. Install two screws to secure valve.
10. Connect wires.
11. Reinstall covers.
42311 070715
TEMP
READY
ENERGY SAVER MODE
ON OFF
HEATER
FIG. 19b
VALVE REMOVAL
Dispense
valve
Bracket
Shroud
19