Service manual

42311 090814
1700W
TANK HEATER
14
LIMIT
THERMOSTAT
BLK
10261.0000E 5/98 © 1987 BUNN-O-MATIC CORPORATION
SCHEMATIC WIRING DIAGRAM HW2
L1
N
BLK BLK WHI
SOL
GREEN
32
BLU/BLK
WHI
WHI
BLK BLK
LIQUID
LEVEL
BOARD
SAFETY SW
(PROBE)
P
N
K
WHI
WHIWHI
WHI
KEEP WARM HEATER
40W
SW. &
THERMOSTAT
KEEP WARM HEATER
40W
120 VOLTS A C
2 WIRE
SINGLE PHASE
RED
RED
White Strip-Tac Plus
Black Ink
Finished Size: 3.5" x 3.5"
≈65% Reduction
TANK HEATER
1 4
LIMIT
THERMOSTAT
BLK
10261.0001G 05/09 © 1998 BUNN-O-MATIC CORPORATION
SCHEMATIC WIRING DIAGRAM HW2A
L1
L2
BLK
BLK
RED
SOL
GRN/YEL
3 2
BLU/BLK
BLK
BLK
LIQUID
LEVEL
BOARD
SAFETY SW
(PROBE)
P
N
K
WHI
WHI
KEEP WARM HEATER
SW. &
THERMOSTAT
KEEP WARM HEATER
230 VOLTS A C
2 WIRE
SINGLE PHASE
RED
RED
RED
RED
RED
White Strip-Tac Plus
Black Ink
Finished Size: 3.50" x 3.50"
~65% Reduction
36