TROUBLESHOOTING (cont.)
Chills but
won’t freeze
Dispenser in
“DAY” mode?
YesNo
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
3- Clean
1
1
3
2
2
1- Done
2- Adjust
Set into
“DAY” mode
Dispenser in
“ICE” mode?
Set into
“ICE” mode
Verify augers
are turned on
Is display showing
UPPER CASE
“ICE” mode?
Is Brix
level high?
Is Filter dirty?
Is Thickness
screen set low?
Have a certified
refrigeration technician
check for low refrigerant
or blockage.
Inspect auger drive shafts
for weak torsion springs or
damaged pins. Check for dirty
or worn seals and bushings.
41084 102709